Caterpillar UPS systems and generator sets are designed for integration into a complete continuous power system. The generator set start module option complements the performance of the continuous power systems, to further assure continuous uninterrupted power to critical loads, no matter the type or duration of power disturbance.
Nominal Output Voltage | 24 VDC |
Input Current - Maximum During Cranking | 32A |
Input Voltage | 380/400/415/480 VAC, 3 phase, 50/60 Hz |
Cat® UPS systems provide constant power protection against surges, sags, and power interruptions that can disrupt operations or cause loss of valuable data or system capacity. Additionally, the use of the optional generator set start module can dramatically increase generator set starting reliability in a continuous power configuration.
Superior system design and the use of robust digital components throughout the system yield the most reliable and trouble-free UPS system on the market. Protection is delivered in the industry's smallest package with the highest efficiency and superior performance.
Nominal Output Voltage | 24 VDC |
Input Current - Maximum During Cranking | 32A |
Input Voltage | 380/400/415/480 VAC, 3 phase, 50/60 Hz |
Storage Temperature | –13° F to 158° F (–25° C to 70° C) |
Dimensions - Floor Mount (w h d) | 34" x 42" x 15" (866.3 mm x 1068.3 mm x 384.4 mm) |
Dimensions - Wall Mount (w x h x d) | 34" x 26" x 15" (866.3 mm x 663.6 mm x 384.4 mm) |
Operating Temperature | –4° F to 122° F (–20° C to 50° C) |
Weight | — |
Humidity | <95% non-condensing |
Cold Cranking Amps. | 1725 Amps (per SAE specifications) |
Nominal Output Current | 1000 Amps |
Cat® UPS systems provide constant power protection against surges, sags, and power interruptions that can disrupt operations or cause loss of valuable data or system capacity. Additionally, the use of the optional generator set start module can dramatically increase generator set starting reliability in a continuous power configuration.
Superior system design and the use of robust digital components throughout the system yield the most reliable and trouble-free UPS system on the market. Protection is delivered in the industry's smallest package with the highest efficiency and superior performance.
The high operating efficiency means yearly savings versus traditional battery UPS products. In addition, lower Cat UPS heat rejection reduces up front HVAC costs and electrical consumption over the life of the product.
By cancelling harmonic distortion, the UPS operates seamlessly with generator sets to provide a higher total electrical load capacity without over sizing the generator set. The UPS effectively insulates the generator set from block loads and transient, and can improve its fault clearing capabilities. Programmable integration with standby generator sets assures greater system reliability and improves the total system operation.
Data not available.