P7.5-1S

P7.5-1S

Overview

The 6.8 - 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.

Specifications

Units: 
Minimum Rating 6.8 kVA / 6.8 kW
Maximum Rating 7.5 kVA / 7.5 kW
Emissions/Fuel Strategy Fuel Optimised
See more

Benefits & Features

Industry Leading Perkins Engine

Alternator

FG100 Control Panel

  May 18, 2024

Specifications

Units: 
Generator Set Specifications
Minimum Rating 6.8 kVA / 6.8 kW
Maximum Rating 7.5 kVA / 7.5 kW
Emissions/Fuel Strategy Fuel Optimised
50 Hz Prime 6.8 kVA / 6.8 kW
50 Hz Standby 7.5 kVA / 7.5 kW
60 Hz Prime - / -
60 Hz Standby
Frequency 50 Hz
Speed 1500 RPM
Voltage 230-240 Volts
50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
50 Hz Standby Rating Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Engine Specifications
Engine Model Perkins® 403A-11G1
Bore 77.0 mm (3.0 in)
Stroke 81.0 mm (3.2 in)
Governor Type Mechanical
Displacement 1.1l (69.0 cu. in)
Compression Ratio 23:01

Benefits & Features

Industry Leading Perkins Engine

Industry Leading Perkins Engine

The Perkins 400 Series engines offer highly competitive performance, fuel economy and EUIIIa Emissions compliance on selected nodes. These engines have been designed and proven in the field in a wide variety of applications. Not only are they reliable but also offer low cost of ownership and excellent fuel economy.

Alternator

Alternator

Benefiting from a choice of leading alternators, the FG Wilson FGL and Leroy Somer brand alternators are known worldwide for providing power generation expertise and solutions offering longlife products with low maintenance. Offering excellent performance and motor starting capacility they have been designed specifically to suit the FG Wilson generator set

FG100 Control Panel

FG100 Control Panel

The FG100 offers simple, intuitive menu navigation and control of your generator set operations, key features such as remote monitoring allow you to control your generator set with ease. Key information is displayed via the LCD display using universally recognised symbols, eliminating the need for complex instructions or language settings. Rainbow SCADA PC software allows for remote ol of your generator set.

Testing & Validation

Testing & Validation

Fully prototype tested with certified torsional vibration analysis available

Cooling System

Cooling System

Designed to operate in ambient temperatures up to 55oC

Standard Equipment

  • Engine
    • Air Cleaner
    • Lube oil drain valve
    • Engine filled with lubrication oil
    • High Coolant Temperature Shutdown
    • Low Oil Pressure Shutdown
  • Cooling
    • Package mounted radiator
    • Radiator & Cooling Fan
    • Coolant Drain Valve
    • Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
    • Cooling System filled with Coolant mix
  • Exhaust
    • Exhaust flange outlet
    • Exhaust stub pipe and gasket
  • Fuel
    • 8 Hr Fuel Tank or Skidbase
    • Fuel Fittings for Local and Remote Feed
  • Alternator
    • FG Wilson Alternator
    • SHUNT Excitation
    • IP23 Protection
  • Control Panel
    • FG100
  • Mounting
    • Skid Base, Formed Steel
    • Anti-vibration mounts
    • Base, Formed Steel with Skid base or Single wall Fuel Tank
    • Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
    • Anti-vibration mounts
    • Battery Tray and Cables

Optional Equipment

  • Exhaust
    • Industrial, Residential, Critical Silencers
  • Alternator
    • Leroy Somer Alternator
    • Quadrature Droop Kit
    • Anti-Condensation Heater and Panel Circuitry
  • Control Panels
    • DSE4520
    • DSE7320
    • DSE7410
    • Deep Sea DSE7420
  • Starting/Charging
    • Lead Acid battery (Dry)
  • General
    • 8 Hour, 600L, 1000L, 2000L fuel tanks
    • Dual wall fuel tanks
    • Upgrade to Standard Set for "CE" Certification
    • EEC Declaration of Conformity
    • Narrow, Wide or Skid Base
    • Sound attenuated, steel or galvanised enclosure
    • Dual wall fuel tanks
  • Enclosure
    • Compliance to European Community Directive 2000/14/EC
    • Super sound attenuation for residential areas
    • Totally enclosed exhaust silencing system
    • Robust and highly corrosion resistant construction

View 360