/  Power Systems  /  Electric Power  /  UPS-Flywheel

UPS Generator Set Start ModuleNon-Current

UPS Generator Set Start Module

Overview

Caterpillar UPS systems and generator sets are designed for integration into a complete continuous power system. The generator set start module option complements the performance of the continuous power systems, to further assure continuous uninterrupted power to critical loads, no matter the type or duration of power disturbance.

Specifications

Units: 
Nominal Output Voltage 24 VDC
Input Current - Maximum During Cranking 32A
Input Voltage 380/400/415/480 VAC, 3 phase, 50/60 Hz
See more

Benefits & Features

Product Features

    • Smallest available footprint
    • 98% total system efficiency
    • Simple cost-effective installation
    • Modular, scalable, redundant architecture
    • Low service and maintenance
    • Cost-effective lifecycle cost
    • Harmonic cancellation
    • Transient protection
    • High-speed voltage regulation
    • Power factor correction
    • Low input current distortion
    • Top and bottom cable entry
    • 40° C rating on entire system
    • Rapid recharge time
    • Utilizes flywheel energy storage technology
    • Color Touch-screen operator interface
    • Optional generator set start module
    • Optional paralleling capability

Reliable Power Protection for Critical Applications

Cat® UPS systems provide constant power protection against surges, sags, and power interruptions that can disrupt operations or cause loss of valuable data or system capacity. Additionally, the use of the optional generator set start module can dramatically increase generator set starting reliability in a continuous power configuration.

Superior Design

Superior system design and the use of robust digital components throughout the system yield the most reliable and trouble-free UPS system on the market. Protection is delivered in the industry's smallest package with the highest efficiency and superior performance.

  April 24, 2024

Specifications

Units: 
Technical Summary
Nominal Output Voltage 24 VDC
Input Current - Maximum During Cranking 32A
Input Voltage 380/400/415/480 VAC, 3 phase, 50/60 Hz
Storage Temperature –13° F to 158° F (–25° C to 70° C)
Dimensions - Floor Mount (w h d) 34" x 42" x 15" (866.3 mm x 1068.3 mm x 384.4 mm)
Dimensions - Wall Mount (w x h x d) 34" x 26" x 15" (866.3 mm x 663.6 mm x 384.4 mm)
Operating Temperature –4° F to 122° F (–20° C to 50° C)
Weight
Humidity <95% non-condensing
Cold Cranking Amps. 1725 Amps (per SAE specifications)
Nominal Output Current 1000 Amps

Benefits & Features

Product Features

    • Smallest available footprint
    • 98% total system efficiency
    • Simple cost-effective installation
    • Modular, scalable, redundant architecture
    • Low service and maintenance
    • Cost-effective lifecycle cost
    • Harmonic cancellation
    • Transient protection
    • High-speed voltage regulation
    • Power factor correction
    • Low input current distortion
    • Top and bottom cable entry
    • 40° C rating on entire system
    • Rapid recharge time
    • Utilizes flywheel energy storage technology
    • Color Touch-screen operator interface
    • Optional generator set start module
    • Optional paralleling capability

Reliable Power Protection for Critical Applications

Cat® UPS systems provide constant power protection against surges, sags, and power interruptions that can disrupt operations or cause loss of valuable data or system capacity. Additionally, the use of the optional generator set start module can dramatically increase generator set starting reliability in a continuous power configuration.

Superior Design

Superior system design and the use of robust digital components throughout the system yield the most reliable and trouble-free UPS system on the market. Protection is delivered in the industry's smallest package with the highest efficiency and superior performance.

Lower Total Cost

The high operating efficiency means yearly savings versus traditional battery UPS products. In addition, lower Cat UPS heat rejection reduces up front HVAC costs and electrical consumption over the life of the product.

Generator Set Integration

By cancelling harmonic distortion, the UPS operates seamlessly with generator sets to provide a higher total electrical load capacity without over sizing the generator set. The UPS effectively insulates the generator set from block loads and transient, and can improve its fault clearing capabilities. Programmable integration with standby generator sets assures greater system reliability and improves the total system operation.

Worldwide Product Support

  • Parts Distribution Centers are located worldwide with available service support through Caterpillar and the Cat Dealer Network.
  • Factory certified service

Standard Equipment

  • <ul> <li>Diode coupling allows battery paralleling/best source selection</li> <li>Auto resetting thermal protection</li> <li>AC disconnect</li> <li>Wall or Floor Mounting</li> <li> Outdoor rated enclosure</li> <li>Rated for 10 crank cycles</li> <li>Remote status contact</li></ul>

Optional Equipment

  • <ul> <li>Upstream AC overcurrent protection/ disconnecting means required</li> </ul>

View 360