XQ1140 Tier 4 Final

XQ1140 - Diesel

Overview

XQ1140 Rental Power Generator Set.

Specifications

Units: 
Rating Prime 910 ekW (1136 kVA)
Frequency 60 Hz
Voltage 120 - 600V
See more

Benefits & Features

Rental ready

Robust, durable product with a range of rental ready features to meet job requirements and applications.

Fuel/Emissions Strategy

Meets U.S. EPA Tier 4 Final emission standards and CARB certified for non-road mobile applications at all 60 Hz ratings.

Cat C18 Diesel Engines

Dual Cat C18 ACERT™ heavy-duty diesel engines. Industry proven reliability.

  September 2, 2024

Specifications

Units: 
Generator Set
Rating Prime 910 ekW (1136 kVA)
Frequency 60 Hz
Voltage 120 - 600V
Rating Standby 1000 ekW (1250 kVA)
Engine
Engine Cat C18
Fuel Diesel
Dimensions
Height - Without Trailer
Length - Without Trailer
Width - Without Trailer
Weight with Lube Oil and Coolant, Without Trailer
Fuel Consumption
100% Load 60Hz
75% Load 60Hz
50% Load 60Hz
100% Load 60Hz
75% Load 60Hz
50% Load 60Hz
Noise rating (with enclosure)
Sound Power @ 7 meters (23 feet) @ All Ratings 76 dB(A)

Benefits & Features

Rental ready

Robust, durable product with a range of rental ready features to meet job requirements and applications.

Fuel/Emissions Strategy

Meets U.S. EPA Tier 4 Final emission standards and CARB certified for non-road mobile applications at all 60 Hz ratings.

Cat C18 Diesel Engines

Dual Cat C18 ACERT™ heavy-duty diesel engines. Industry proven reliability.

CAT EMCP 4.4 Digital Controls

Dual EMCP 4.4 easy to use digital controls with manual and automatic paralleling capability.

Cat LC Series Generators

Class H Insulation. Integrated voltage regular for fast response in demanding applications.

HMI Controls

Externally Mounted Color Touch-Screen HMI Control Center

Cat Connect

Remote monitoring for fleet management and asset tracking

Sound Attenuated Container

77 dBA @ 7m Sound Performance @ 75% Prime Load. 40' ISO high cube container, 9-high stack CSC certified Service and Personnel doors. Externally-accessible controls

500 hr oil change intervals

Reducing operating costs and producing less waste

Reduced Environmental Impact

110% Spill Containment of On-Board Engine Fluids.

Factory designed, built and tested

Single-source Supplier

Worldwide Product Support

    • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
    • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Additional options

Two-axle, air-ride traler with anti-lock brakesystem
Extended Service interval kits
600V generator

Standard Equipment

  • Cat C18 Diesel Engines
    • Two Cat C18 Diesel Engines
    • Reliable, rugged, durable design
    • EPA Tier 4 Final and CARB Emissions Certified
    • Turbocharged Aftercooled
    • Aftertreatment module. </br> DEF System</br>
  • Alternator and Alternator attachments
    • 3 Phase, brushless, 12 lead, Permanent Magnet Excited
    • LC6134G Frame
    • Anti-condensation space heaters
    • Integrated voltage regulator (IVR) with VAR/PF control
    • Sized for 105°C temperature rise at 40°C ambient
  • Control Panels
    • Dual EMCP 4.4 genset mounted digital controllers
    • Externally accessible Color Touch-Screen HMI Control Center
    • Manual and automatic paralleling capability
  • Governing system
    • Electrical governing system ADEM™ A4
  • Cat Connect remote monitoring
    • Provides package monitoring and management
  • Cooling System
    • Vertically mounted radiator with vertical airdischarge from the container
    • Provides 47°C ambient capability at Prime rating
  • Charging / Starting System
    • UL Listed and CSA Certified 240V, 20 Amp battery charger
    • Charging alternator; 24V-80A, heavy duty withintegral regulator and belt guards
    • Solar maintainer for batteries
    • Single electric starting motor, 24V per engine
  • Fuel System
    • 630-gal (2385 L) double-wall fuel tank, UL 142and ULC 601 Listed and complies with Transport Canada requirements, internal and external fuel fill
    • Fuel tanks connected by fuel transfer system withfilter to allow both engines access to all fuel on-board
    • Primary and secondary fuel filters
    • Fuel cooler
  • Air inlet system
    • Heavy-duty air element, canister type
  • Distribution
    • Externally accessible, Vibration Isolated, 3600A Frame, 1000 Ka, IC, 3-pole electrically operated breaker with lock out tag out provision
    • Busbar connections
    • Dual customer connections
  • Sound Attenuated Container
    • 40' ISO high cube container
    • Sound level is 76 dB(A) at 7 meters per SAEJ1074 measured at 75% prime load
    • Sound attenuated air intake louvers and fivelockable personnel doors with panic release
  • Lube System
    • Pump, integral oil cooler, lube oil, filter, filler and dipstick, and oil sampling valve
    • Oil drain line with internal brass ball valve routedto connection point accessible from exterior
  • General
    • Factory tested and inspected
    • Full manufacturer's warranty
    • UL, NEMA, ISO, and IEEE standards

Optional Equipment

  • Trailer
    • Two-axle, air-ride chassis with anti-lock brake system

View 360