CG260-16

CG260-16

Overview

From natural gas-fueled combined heat and power (CHP) systems and emergency power for facilities, to renewable biogas energy to support the local grid, or electricity generated from coal mine gases, Caterpillar has a wide range of reliable gas power solutions.

Specifications

Units: 
Continuous Rating 4300 / 4000 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 25%)
Maximum Electrical Efficiency 44.1 / 43.8%
See more

Benefits & Features

High Reliability

    • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
    • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
    • Higher reliability and lower maintenance costs due to open combustion chamber technology

High Availability, High Profitability

    • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
    • More profit for your plant
    • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
    • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)

Optimized Lubrication Consumption

    • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets
    • Improved components reduce lube oil consumption
    • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products

  August 27, 2024

Specifications

Units: 
Generator Set Specifications
Continuous Rating 4300 / 4000 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 25%)
Maximum Electrical Efficiency 44.1 / 43.8%
Maximum Standby Rating 4500 ekW
Frequency 50 / 60 Hz
RPM 1000 / 900 rpm
Engine Specifications
Engine Model CG260-16
Displacement
Aspiration TA
Bore
Stroke
Generator Set Dimensions
Length
Width
Height
Dry Weight - Genset

Benefits & Features

High Reliability

    • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
    • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
    • Higher reliability and lower maintenance costs due to open combustion chamber technology

High Availability, High Profitability

    • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
    • More profit for your plant
    • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
    • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)

Optimized Lubrication Consumption

    • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets
    • Improved components reduce lube oil consumption
    • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products

Standard Equipment

  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TEM (Total Electronic Management)
  • Cooling
    • flange connections for JW inlet and outlet
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
  • Exhaust
    • Exhaust waste gate for the CG260-16
    • Closed crankcase ventilation system
  • Fuel system
    • Electronic fuel metering valve
    • Independently controlled cylinder monitoring and ignition system
    • Pre-chamber spark plugs
  • Generator
    • Busbar connections
    • Closed-coupled generator result in no torque transmission to the base frame
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • Grid code generator
    • Anti-condensation space heater
    • Winding temperature detectors
  • Starting/Charging
    • Compressed air engine start
  • General
    • Crankshaft vibration damper and guard

Optional Equipment

  • Cooling
    • CHP skid
  • Grid Code Compliance
    • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands

View 360