C4.4 (60 Hz)

C4.4 (60)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Units: 
Maximum Rating 100 ekW
Minimum Rating 36 ekW
Emissions/Fuel Strategy Non Regulated, EU Stage II
See more

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

R-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

  October 8, 2024

Specifications

Units: 
Generator Set Specifications
Maximum Rating 100 ekW
Minimum Rating 36 ekW
Emissions/Fuel Strategy Non Regulated, EU Stage II
Voltage 220 to 480 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Prime
Engine Specifications
Engine Model C4.4, In-line 4, 4-cycle diesel
Bore
Stroke
Displacement
Compression Ratio 18.2:1
Aspiration Turbocharged
Fuel System Electronic (adjustable)
Governor Type Adem™A4
Generator Set Dimensions
Length - Maximum
Width - Maximum
Height - Maximum

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

R-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

GCCP 1.3 Control Panel

    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements
    • Image may not be a representative of actual product

Cooling System

    • Designed to operate in standard ambient temperatures up to 55°C (131°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

One Safe Source

    • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
    • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
    • Each generator set package is tested before leaving the Caterpillar facility
    • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

    • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
    • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Air Inlet
    • Air cleaner
  • Cooling
    • Package mounted radiator
  • Cooling System
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Caterpillar extended life coolant
  • Exhaust
    • Exhaust flange outlet
  • Control Panel
    • GCCP 1.3
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Fuel
    • Secondary fuel filters
    • Primary fuel filter with integral water separator
    • Fuel priming pump
  • Generator
    • Segregated low voltage (AC/DC) wiring panel
    • Voltage regulator (single phase sensing)
    • Matched to the performance and output characteristics of Cat engines
    • 12 Leads
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • Tower panel, IP22, bottom cable entry
    • IP23 Protection
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Power Termination
    • Busbar
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
  • Mounting
    • Rubber vibration isolators
  • Starting/Charging System
    • 24V battery with rack and cables
  • General
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • Engine and alternator pre-paint, Caterpillar yellow
  • Starting/Charging
    • 24 volt starting motor
    • Batteries

Optional Equipment

  • Exhaust
    • Industrial, residential, critical mufflers
  • Generator
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
    • Anti-condensation heater
  • Alternator System
    • 3 phase sensing
    • Permanent magnet excitation (PMG)
    • R Frame auxilliary winding
    • Quadrature droop kit
    • LC Frame alternator with coastal insulation protection
  • Circuit breakers
    • Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
  • Power Termination
    • Circuit breakers, IEC compliant
    • Circuit breakers, UL listed
  • Control Panels
    • GCCP 1.3
    • Load share module
    • Digital I/O module
    • Remote monitoring software
    • Local & remote annunciator modules
  • Cooling System
    • Coolant heater
    • Low coolant level shutdown
    • Low coolant temperature alarm
  • Control Panel Options
    • Earth fault (2 wire only)
    • GCCP 1.3
    • Volt free contacts
    • Emergency stop with key
    • Battery charger
    • Panel mounted audible alarm
    • Control panel heater
    • Speed adjust potentiometer
    • Voltage adjust potentiometer
    • Earth leakage (2 wire only)
    • Overload shutdown via breaker
  • Starting/Charging
    • Jacket water heater
    • Charging alternator
    • Heavy duty starting system
    • Battery chargers
    • Oversize batteries
  • Enclosures
    • Sound attenuated Level 2 enclosure
    • Sound attenuated Level 1 (galv)
    • Rental pack - CAE rental option only
  • European Certifications
    • Upgrade to STD set for CE
  • Fuel System
    • Compact skidbase for open set
    • Low fuel level alarm
    • Low fuel level shutdown
    • Bunded fuel tank
    • Open set narrow tankbase
    • Skidbase for CALG enclosure sets
    • High fuel level alarm
  • General
    • Single or dual wall sub-base fuel tanks
    • EU Certificate of Conformance (CE)
    • CSA Certification
    • Single or dual wall integral fuel tanks
    • Automatic transfer switches (ATS)
    • Narrow, wide or skid base
    • UL 2200 package
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • EEC Declaration of Conformity
    • Integral & sub-base fuel tanks
  • Global Certifications
    • Certification for CIS
  • Mounting Options
    • Battery removal
    • Electronic governor
    • Industrial silencer
    • Silencer installation kit
    • External single point lift - enclosure
  • Special Packing/Inspectons for Shipment
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • General - Accessories / Miscellaneous
    • Packing case - compact set
    • Stone guards/rad trans flange
    • Packing case - canopied set

View 360