3412C | 750kVA

3412C | 750 kVA 50Hz Low Fuel Consumption

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Units: 
Maximum Rating 680 kVA
Minimum Rating 680 kVA
Emissions/Fuel Strategy Low Fuel Consumption
See more

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR500 Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

  September 13, 2024

Specifications

Units: 
Generator Set Specifications
Maximum Rating 680 kVA
Minimum Rating 680 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Prime
Engine Specifications
Engine Model 3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
Stroke
Displacement
Compression Ratio 13:01
Aspiration Turbocharged, Air to Air Aftercooled
Fuel System Pump and Lines
Governor Type ADEM™ A5
Generator Set Dimensions
Length - Maximum
Width - Minimum
Width - Maximum
Height - Maximum
Dry Weight - Genset (minimum)
Dry Weight - Genset (maximum)

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR500 Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

EMCP 4 Control Panel

    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements

Cooling System

    • Designed to operate in standard ambient temperatures up to 50°C (122°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

    • EU Declaration of Conformity
    • EU Declaration of Incorporation
    • Eurasian Conformity (EAC)

One Safe Source

    • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
    • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
    • Each generator set package is tested before leaving the Caterpillar facility
    • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

    • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
    • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air Inlet System
    • Air cleaner, single element canister type with service indicator
  • Control Panel
    • GCCP Control panel
    • Over/under voltage (27 / 59)
    • Environmental sealed front face
    • Generator phase sequence
    • Communications
    • Digital I/O module
    • Features include:
    • 2 Programmable relay outputs (Form C)
    • Compatible with the following optional modules:
    • Customer data link (Modbus RTU)
    • 4 programmable relay outputs (Form A)
    • Amps (per phase & average)
    • kVA (per phase, average & percent)
    • Text alarm/event descriptions
    • Low coolant level
    • Generator temperature monitoring module
    • Run/auto/ stop/control
    • Overspeed
    • Serial annunciator module data link
    • Emergency stop pushbutton
    • Frequency (Hz)
    • RPM
    • 6 programmable digital inputs
    • Oil pressure (psi, kPa or bar)
    • Engine cycle crank
    • Operating hours
    • Local annunciator
    • coolant temperature
    • kW-hr (total)
    • Programmable protective relaying functions:
    • kW (per phase, average & percent)
    • Low oil pressure
    • Reverse power (kW) (32)
    • Remote Serial annunciator
    • DC volts
    • Power factor (per phase & average)
    • Remote CAN annunciator
    • 24 Volt DC operation
    • Accessory module data link
    • Failure to start (overcrank)
    • Over/under frequency (81 o/u)
    • kVAr (per phase, average & percent)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Low coolant temperature
    • 2 Programmable digital outputs
    • Reverse reactive power (kVAr) (32RV)
    • Emergency stop
    • Digital indication for:
    • High coolant temperature
    • Speed adjust
    • Voltage adjust
    • Volts (L-L & L-N)
    • Overcurrent (50 / 51)
  • Cooling System
    • Fan and belt guards
    • Coolant drain line with valve, piped to edge of base
    • Caterpillar extended life coolant
    • Coolant level shutdown
    • Radiator with guard (Sized for 50 degrees C)
  • Exhaust System
    • Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
  • Fuel System
    • Flexible fuel lines terminated on base
    • Fuel priming pump
    • Primary and Secondary fuel filters
    • Water seperator
  • Generator and Attachments
    • 3-phase sensing
    • SR4B self excited
    • Class H insulation
    • 2:1 Volts/Hz
    • Reactive droop
    • VR6 voltage regulator
    • Busbar termination
    • Class F temperature rise
    • 12 Leads
  • Governing System
    • Cat electronic governor
  • Lube System
    • Oil drain line with valve, piped to edge of base
    • Lubricating oil
    • Oil filter
    • Fumes disposal, piped to front of radiator
  • Mounting System
    • Base, formed steel with linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • Battery with rack, cables
    • 45 amp Charging alternator
    • 24 volt starting motor
    • Fuel shutoff solenoid

Optional Equipment

  • Air Inlet System
    • Open element air cleaners
    • Heavy duty air cleaners
    • Dual element air cleaners
  • Circuit breakers
    • 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
    • 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
  • Control Panel
    • First local annunicators
    • Local discrete I/O package
    • Generator temperature monitoring package
    • Ground fault relay
    • Remote custom annunicator
    • GCCP Control panel
    • Generator running VFC
    • GCCP Control panel
    • Vandal proof panel door
    • Common alarm/shutdown relay
  • Cooling System
    • Jacket water heaters
    • Radiator duct flange
  • European Certifications
    • Eurasian Conformity (EAC) mark
  • Exhaust System
    • Elbow kit
    • Manifold and turbocharger guards
    • Through wall installation kit
    • Mufflers
  • Generator and Attachments
    • Digital voltage regulator
    • Oversize and premium generators
    • Space heater
    • Permanent magnet excitation (PMG)
  • Lube System
    • Manual sump pump
  • Mounting System
    • Fuel tank base (1200 ltr)
  • Special Tests / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging
    • Heavy duty starting system
    • Battery chargers
    • Battery disconnect switch
    • Oversize batteries
  • Governing System
    • Electronic load share

View 360