DE350S GC (60 Hz)

DE350S GC

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Units: 
Maximum Rating 350 ekW
Minimum Rating 350 ekW
Emissions/Fuel Strategy Low Fuel, R96/EUIIIa
See more

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

  September 13, 2024

Specifications

Units: 
Generator Set Specifications
Maximum Rating 350 ekW
Minimum Rating 350 ekW
Emissions/Fuel Strategy Low Fuel, R96/EUIIIa
Voltage 220 to 480 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Engine Specifications
Engine Model C9.3B ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
Stroke
Displacement
Compression Ratio 16.5:1
Aspiration Air to Air Aftercooled
Fuel System Direct Injection
Governor Type Adem™A4
Generator Set Dimensions
Length - Maximum
Width - Maximum
Height - Maximum

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

GCCP 1.1 Control Panel

    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements

Cooling System

    • Designed to operate in standard ambient temperatures up to 55°C (131°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

One Safe Source

    • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
    • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
    • Each generator set package is tested before leaving the Caterpillar facility
    • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

    • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
    • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Engine
    • C9.3B, Inline 6 cylinder, 4 stroke diesel
  • Air, Cooling & Exhaust
    • Standard air filter
  • Genset Control
    • GCCP 1.1
  • Governor
    • Adem A4
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Air, Cooling & Exhaust
    • 6" Elbow kit
    • No muffler
    • Single stage air filter
    • 6" Elbow kit
    • 5" Muffler - 10 dBA Attenuation
    • 5-6" Exhaust adapter
    • Dual element air filter
    • 6" Muffler - 25 dBA attenuation
    • 5" Elbow kit
    • Canopy silencer
  • Alternator Requirements
    • IP Standard @ 21 FUW A-Frame
    • Space heater
  • Auxiliary Supply Voltage
    • 240V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Circuit breaker
    • 4 Pole Circuit breaker 800A
    • 4 Pole Circuit breaker 1250A
    • Shunt Trip
    • Neutral earth link
    • 3 Pole Circuit breaker 630A
    • 3 Pole Circuit breaker 800A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 630A
    • 3 Pole Circuit breaker 1250A
    • Overload via alarm switch on breaker
    • Auxiliary contacts
  • Enclosure
    • Cat GC enclosure
  • Fuel Storage
    • Low fuel level alarm
    • High fuel level alarm
    • Fuel level sender
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment 01
  • Genset Control
    • Coolant heater
    • PLG Cellular 4G E
    • Battery charger
    • PLG Ethernet
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Oil temperature displays
    • Low coolant temperature alarm
    • Voltage adjust potentiometer
    • Speed adjust potentiometer
    • PLG Cellular 4G U
    • Battery

View 360