DE400 GC

DE400 GC

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Units: 
Maximum Rating 400 kVA
Minimum Rating 400 kVA
Emissions/Fuel Strategy Non-Certified Emissions
See more

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

  June 9, 2022

Specifications

Units: 
Generator Set Specifications
Maximum Rating 400 kVA
Minimum Rating 400 kVA
Emissions/Fuel Strategy Non-Certified Emissions
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby
Engine Specifications
Engine Model C9.3B, I-6, 4-cycle diesel
Bore
Stroke
Displacement
Compression Ratio 16.5:1
Aspiration Turbocharged Air-to-Air Aftercooled
Fuel System Common Rail
Governor Type ADEM™A6
Generator Set Dimensions
Length - Maximum
Width - Maximum
Height - Maximum
Dry Weight - Genset (maximum)

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

GCCP 1.1 Control Panel

    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements

Cooling System

    • Designed to operate in standard ambient temperatures up to 55°C (131°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

    • CE Certification Available
    • CIS Certification Available

One Safe Source

    • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
    • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
    • Each generator set package is tested before leaving the Caterpillar facility
    • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

    • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
    • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Engine
    • C9.3B, Inline 6 Cylinder, 4 Stroke Diesel
  • Air, Cooling & Exhaust
    • Standard Air Filter
  • Genset Control
    • GCCP 1.1
  • Governor
    • Adem A4
  • Alternator
    • A Frame Standard Alternator
  • Fuel Storage
    • Single Wall 8 Hour Tank
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Air, Cooling & Exhaust
    • 6" Elbow Kit
    • Dual Element Air Filter
    • 5-6" Exhaust Adapter
    • Canopy Silencer
    • 5" Elbow Kit
    • 6" Flange Kit
    • 6" Muffler - 25 dBA Attenuation
    • 5" Muffler - 10dBA Attenuation
    • Single Stage Air Filter
    • No Muffler
  • Alternator Requirements
    • IP Standard @ 21 FUW A-Frame
    • Space Heater
  • Auxiliary Supply Voltage
    • 240V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Circuit Breaker
    • 3 Pole Circuit Breaker 800A
    • Circuit Breaker Padlock
    • 4 Pole Circuit Breaker 630A
    • 4 Pole Circuit Breaker 1250A
    • 3 Pole Circuit Breaker 630A
    • 4 Pole Circuit Breaker 800A
    • Overload via Alarm Switch on Breaker
    • Neutral Earth Link
    • 3 Pole Circuit Breaker 1250A
    • Auxiliary Contacts
    • Shunt Trip
  • Enclosure
    • Cat GC Enclosure
  • Fuel Storage
    • Low Fuel Level Shutdown
    • Fuel Level Sender
    • Low Fuel Level Alarm
    • Single Wall Tank With Containment 01
    • High Fuel Level Alarm
    • Dual Wall 8 Hour Tank
  • Genset Control
    • PLG Cellular 4G E
    • Oil Temperature Display
    • Coolant Heater
    • Battery Charger
    • Standby Pack (Smart Jacket Water Heater, Battery Charger)
    • PLG Cellular 4G U
    • Voltage Adjust Potentiometer
    • Low Coolant Temperature Alarm
    • Speed Adjust Potentiometer
    • PLG Ethernet
    • Battery

View 360