C15 (50 Hz) China Non Road

C15 (China Non Road) (50)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Units: 
Maximum Rating 550 kVA
Minimum Rating 365 kVA
Emissions/Fuel Strategy Low Fuel, Tier 2 or 3
See more

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

  September 13, 2024

Specifications

Units: 
Generator Set Specifications
Maximum Rating 550 kVA
Minimum Rating 365 kVA
Emissions/Fuel Strategy Low Fuel, Tier 2 or 3
Voltage 208 to 600 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Prime
Engine Specifications
Engine Model C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
Stroke
Displacement
Compression Ratio 16.1:1
Aspiration Air to Air Aftercooled
Fuel System MEUI
Governor Type Adem™A4
Generator Set Dimensions
Length - Maximum
Width - Maximum
Height - Maximum

Benefits & Features

Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation

GCCP1.3 Control Panel

    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements

Cooling System

    • Designed to operate in standard ambient temperatures up to 55°C (131°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

One Safe Source

    • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
    • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
    • Each generator set package is tested before leaving the Caterpillar facility
    • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Standard Equipment

  • Air System
    • Aftercooler core
    • Turbocharger
    • Air cleaner - Non canister disposable paper filter
  • Air Inlet
    • Air cleaner
  • Control Panel
    • GCCP 1.3
    • GCCP 1.3
  • Cooling
    • Package mounted radiator
  • Cooling System
    • Radiator and cooling fan with guard
    • Coolant drain line with valve
    • Caterpillar extended life coolant
    • Fan drive, battery charging alternator drive
  • Fuel
    • Secondary fuel filters
    • Fuel priming pump
    • Primary fuel filter with integral water separator
  • Exhaust
    • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
    • Exhaust flange outlet
  • Fuel System
    • Standard open set fuel tank/base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generator
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Generator and Attachments
    • IP23 Protection
    • A Frame generator - IP21 Protection
    • Segregated low voltage (AC/DC) wiring panel
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Optional LC Frame generator - IP23 Protection
    • Power center, IP22
    • Integrated voltage regulator (IVR)
  • Power Termination
    • Busbar
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Lubricating oil
    • Oil drain valves
  • Mounting
    • Rubber vibration isolators
  • Mounting System
    • Rubber vibration isolators
  • Starting/Charging
    • 24 Volt battery with rack and cables
    • Batteries
    • 24 volt starting motor
  • General
    • Engine and alternator pre paint, Caterpillar yellow
    • Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment

  • Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
  • Exhaust
    • Industrial, residential, critical mufflers
  • Certifications
    • EU Certificate of Conformance (CE)
    • Global certification for CIS
  • Generator
    • Oversize and premium generators
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Circuit breakers
    • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
    • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
    • Auxiliary contacts, circuit breaker
    • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • Padlockable circuit breaker device
    • Power terminal strip
    • Shunt trip for IEC circuit breaker
    • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Control Panels
    • Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • Remote annunciator module
    • Oil temperature displays
    • GCCP 1.4
    • Local annunciator
    • Local alarm horn
    • Volt free contacts
  • Starting/Charging
    • Jacket water heater
    • Heavy duty starting system
    • Battery chargers
    • Oversize batteries
    • Charging alternator
  • Cooling System
    • Radiator duct flange
    • Stone guards
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • Manifold and turbocharger guards
    • Flexible exhaust fittings
    • 6 and 8 inch flange GP
    • 6 and 8 inch elbow kit
    • Engine mounted muffler
  • Fuel System
    • Dual wall fuel tank base
    • Manual fuel transfer pump
    • Fuel transfer system controls
  • General
    • UL 2200 package
    • Automatic transfer switches (ATS)
    • Narrow, wide or skid base
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Single or dual wall sub-base fuel tanks
    • EU Certificate of Conformance (CE)
    • EEC Declaration of Conformity
    • The following options are based on regional and product configuration:
    • Single or dual wall integral fuel tanks
    • CSA Certification
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Integral & sub-base UL listed dual wall fuel tanks
  • Generator and Attachments
    • Oversize A Frame generator
    • LC frame generator
    • Oversize LC frame generator
    • CIP A Frame generator
    • LC frame CIP generator
    • Permanent magnet excitation (PMG) generator
    • Space heaters
    • Ingress protection
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base
  • Special Test / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Battery disconnect switch

View 360