DG230 GC (3 phase)

DG230 GC (3 phase)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Units: 
Frequency 60 Hz
Natural Gas Rating 230 eKW
Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application
See more

Benefits & Features

Engine

    • Four-stroke-cycle gas engine combines consistent performance and excellent fuel economy with minimum weight

Generator

    • Matched to the performance and output characteristics of Cat engines
    • Industry leading mechanical and electrical design
    • Industry leading motor starting capabilities
    • High Efficiency

Cat EMCP Control Panel+17:21

The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

  February 29, 2024

Specifications

Units: 
Generator Set Specifications
Frequency 60 Hz
Natural Gas Rating 230 eKW
Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application
Speed 1800 rpm
Engine Specifications
Aspiration Turbocharged - Aftercooled
Governor Type Electronic
Bore
Stroke
Generator Set Dimensions
Length
Width
Height
Weight

Benefits & Features

Engine

    • Four-stroke-cycle gas engine combines consistent performance and excellent fuel economy with minimum weight

Generator

    • Matched to the performance and output characteristics of Cat engines
    • Industry leading mechanical and electrical design
    • Industry leading motor starting capabilities
    • High Efficiency

Cat EMCP Control Panel+17:21

The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

Design Criteria

    • The generator set facilitates compliance with NFPA 110 and meets ISO 8528-5 requirements for transient response
    • Cooling system designed to operate in 50˚C/122˚F ambient temperatures with an air flow restriction of 0.5 in. water

UL 2200 / CSA - Optional

    • UL 2200 listed packages
    • CSA Certified
    • Certain restrictions may apply.
    • Consult with your Cat® Dealer.

Worldwide Product Support

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries.

Standard Equipment

  • Cooling
    • Factory-installed radiator
    • Closed coolant recovery system
    • 50/50 Ethylene glycol antifreeze
    • Radiator and cooling fan complete with protective guards
    • Standard ambient temperatures up to 50°C (122°F)
  • Air Inlet
    • Single element air filter
  • Fuel
    • Low fuel pressure switch
    • Primary and secondary fuel shut-off
    • Fuel pressure test po
    • Dual lock off valves
    • Natural Gas or LP Vapor
    • NPT connection
  • Generator
    • Class H insulation material
    • Full load capacity alternator
    • Permanent magnet excitation
    • Class H insulation material
    • Full load capacity alternator
    • Integrated Voltage Regulator
    • Matched to the performance and output characteristics of Cat engines
    • Permanent magnet excitation
    • IP23 Protection
  • Exhaust
    • Exhaust outlet with 3” pipe
  • Controls
    • EMCP 4.2 Series generator set controller
  • Mounting
    • Vibration isolaton (puck type)
    • Rubber vibration isolators
  • Electric Power - Package Serial Number Prefix
    • Battery charging alternator
  • Electric Starting and/or Prelube
    • Battery cables
    • Engine electrical system
    • Solenoid activated starter motor
    • Solenoid activated starter motor
  • Governor
    • Electronic governor (non adjustable)
  • Control Panel
    • EMCP 4.2 Series generator set controller
  • Starting/Charging
    • Batteries with rack and cables
    • 12 volt starting motor

Optional Equipment

  • Starting/Charging
    • Battery heater
    • Charging alternator
    • Jacket water heater
    • Battery charger – UL Listed 10 amp
  • General
    • Suitable for Use as Service Equipment (SUSE)
    • Automatic transfer switches (ATS)
    • CSA Certification
    • Enclosures: sound attenuated, weather protective
    • UL 2200 package
  • Generator
    • Anti-condensation heater
    • Shunt trip and auxiliary contact breaker
    • Thermal magnetic or electronic trip MCCBs
    • Excitation: [ ] Permanent Magnet Excited (PM)
    • Anti-condensation heater
    • Oversize and premium generators

View 360