CPM300SNon-Current

CPM300S

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Specifications

Units: 
Governor Type ADEM™A4
Voltage 400 VAC 3-Phase, 3 wire plus ground
Continuous Power Output 300 kVA (240 kW @ PF 0.8)
See more

Benefits & Features

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • IP 23 Protection

Certification and Standards

 EU Certificate of Conformance  2006/42/EC Machinery Directive (MD)  2006/95/EC Low Voltage Directive (LV)  89/336/EEC EMC Directive  EN 12601 Reciprocating internal combustion engine driven generating sets  EN 61439 Low voltage switchgear and control gear assemblies  EN 62040-1 Uninterruptible Power Systems (UPS) – General and safety requirements for UPS  EN 60204 Safety of machinery – Electrical equipment of machines  2000/14/EC Noise emission by outdoor

  April 5, 2024

Specifications

Units: 
Generator Set Specifications
Governor Type ADEM™A4
Displacement
Fuel System MEUI™
Engine Model C13 ATAAC, I-6 4-stroke water-cooled diesel
Electrical Power Output 350 kVA Standby Power Rated
Generator Frame Size LC6114B
Model Cat C13
Generator Excitation Self Excitation
Generator Voltage Regulator Single phase sensing (Optional 3 phase sensing)
Generator Voltage Regulation +/- 0.5% (steady state)
CPM300 Specifications
Voltage 400 VAC 3-Phase, 3 wire plus ground
Continuous Power Output 300 kVA (240 kW @ PF 0.8)
Dimensions (ISO 20 ft High Cube) 6,058 x 2,438 x 2,896 mm / 239 x 96 x 114 in
Noise Level - Generator Online 85 dBA@1m
Weight 14000 kg / 31000 lbs
Frequency 60 Hz +/- 10% max (programmable)
UPS Specifications
Maximum Continuous Input 400
Input Voltage 480 VAC 3‐Phase, 3 wire plus ground
Maximum kVA / (kW) 300 (240)
Flywheel Type 300 Series Single Module System (SMS)
Certifications UL 1778 listed, EN62040-3, CUL CAN/CSA 22.2
AC Output Current at 480 VAC (amps) 361
AC Output Frequency 60 Hz (mains synchronized) normal operation, +/- .2% free running
Input Voltage Range +10% / ‐15% (programmable)
AC Output Voltage 480 VAC 3‐Phase, 3 wire plus ground

Benefits & Features

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • IP 23 Protection

Certification and Standards

 EU Certificate of Conformance  2006/42/EC Machinery Directive (MD)  2006/95/EC Low Voltage Directive (LV)  89/336/EEC EMC Directive  EN 12601 Reciprocating internal combustion engine driven generating sets  EN 61439 Low voltage switchgear and control gear assemblies  EN 62040-1 Uninterruptible Power Systems (UPS) – General and safety requirements for UPS  EN 60204 Safety of machinery – Electrical equipment of machines  2000/14/EC Noise emission by outdoor

World Wide Product Support

 Cat Dealers provide extensive post sale support including maintenance and repair agreements.  One single service contract for the complete Cat CPM  Cat dealers have over 1,800 dealer branch stores operating in 200 countries.  The Cat S•O•SSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

UPS Generator Set Integration

By cancelling harmonic distortion, the UPS operates seamlessly with the generator set to provide a higher total electrical load capacity without oversizing the generator set. Cat UPS effectively insulates the generator set from block loads and transient, and can improve its fault clearing capabilities. The CPM is factory tested and all programmable integration parameters adjusted at factory that assures greater system reliability and improves the total system operation.

UPS Lower Operating Cost

Caterpillar's high operating efficiency (>97%) means yearly savings versus traditional battery UPS products. In addition, lower Cat UPS heat rejection reduces up front HVAC costs and electrical consumption over the life of the product.

UPS Superior Design

Superior system design and the use of robust digital components throughout the system yield the most reliable and trouble-free UPS system on the market. Protection is delivered in the industry's smallest package with the highest efficiency and superior performance.

Automatic Transfer Switch

A 4-pole, Open Transition Automatic Transfer Switch will switch the load between the utility source and the generator. It is fully rated to the generator output and incorporates convenient customer connections for Continuous and Non-critical load. Connection points are also available for load bank testing or a rental generator set.

Standard Equipment

  • Flywheel Energy Storage
    • Compact, battery free, low cost maintenance / operation
  • Starting System
    • GenStart module provides up to 1725 cold cranking amps @ 24 VDC and is redundant to the generator set starting batteries for highest system reliability. Battery charger integrated.
  • Control system
    • LCD monitor/control HMI panel installed on UPS/ATS/Generator set. Monitoring and alarms for critical components with self-diagnostics. Two (2) warning tower lights installed on exterior of container.
  • Communication with Integrated System
    • Integral modem for remote communication. MODBUS (RTU or TCP/IP). Remote notification and monitoring via Ethernet and e-mail. RS232 or RS485 serial connection. Real-time monitoring software available (UPS View / EMCP Monitoring Software).
  • Cooling System
    • Louvers installed on input and output of the container. Redundant cooling fans on UPS with speed regulation by temperature control unit.
  • Engine Coolant System
    • Jacket water heater. Coolant level sight gauge.
  • Switchgear Integration
    • Automatic Transfer Switch (ATS) – controlled by microprocessor-based unit. Integrated maintenance bypass. Convenient customer connection for continuous load and non-critical load output. Fuel System Integrated fuel system with fuel tank, primary fuel filter with integral water separator,
  • Fuel System
    • Integrated fuel system with fuel tank, primary fuel filter with integral water separator, secondary fuel filters and fuel priming pump.

View 360