CN1566 Electric Motor

CN1566 Electric Motor for Gas Compression

Overview

Get power built for your most demanding gas compression applications. Every Cat® electric motor is tested at each stage of production to make sure it performs reliably under load and according to your process requirements. High operating efficiency and low operating costs come with low noise levels and no emissions. Cat electric motors for gas compression are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.

Specifications

Units: 
Voltage/Frequency 4000V ± 10%/60 Hz
Type of EX-Protection Class 1 Division 2 Group A,B,C,D T3 (NEC or CEC)
Mounting Designation F1 or F2
See more
  February 29, 2024

Specifications

Units: 
Electric Motor Specifications
Voltage/Frequency 4000V ± 10%/60 Hz
Type of EX-Protection Class 1 Division 2 Group A,B,C,D T3 (NEC or CEC)
Mounting Designation F1 or F2
Number of Poles
Electric Motor Type Squirrel Cage Induction Motor
Full Load Speed
Shaft
Standards NEMA MG1
Connection of Stator Winding Star
Locked Rotor Torque 60%
No Load Current 67 Amps
Locked Rotor Amps 500% Code E
Service Factor 1.15 SF (1.0 VFD)
Enclosure Type/Method of Cooling WP-II
Duty Continuous
Temperature Rise Class B at rated load
Maximum Ambient Temperature
Maximum Altitude - Before Derate
Rated Torque
Full Load Current 202 Amps
Insulation Class F

Benefits & Features

Data not available.

Standard Equipment

  • Bearings
    • Bearing RTDs for temperature monitoring
    • Insulated non-drive end bearings to reduce bearing currents
    • Anti-friction on 1500 hp (optional)
  • Rotors
    • Designed for minimal vibration
    • Dynamic balancing at full operational speed
    • Fabricated copper squirrel cages
    • Oversized, forged, keyless shaft
    • AISI 4140/DIN42CrMo4 shaft
  • Stators
    • Radial air ducts ensure uniform and efficient cooling
    • Vacuum pressure impregnated with specially formulated epoxy resin
    • 2X RTDS per Phase
    • Space heater
    • Welded and machined stator core retains its rigidity throughout motor life to ensure a sealed and homogeneous insulation system that results in high dielectric strength, excellent heat transfer and the elimination of hazardous internal partial discharges

View 360