Power Grid Stabilization (PGS) Module

Power Grid Stabilization (PGS) 20' Module

Overview

The Cat® Power Grid Stabilization (PGS) module is a scalable, rapidly deployable energy storage system. The PGS integrates with solar or other renewable sources to provide short duration power when the renewable source is not available. The PGS also provides reserve power to optimize generator set operation. The system may provide temporary backup power to facilities in the event of a power outage.

Specifications

Units: 
Application Transient Assist
Module Type Grid stabilization
Nameplate Power 767 kW | 1000 kW
See more

Benefits & Features

Reliable and Scalable

    Factory prepackaged and tested
    • Pre-engineered containershipped as a single unit with batteries, inverter, isolation transformer and other equipment installed.
    • Parallel ready - multiple modules may be used in parallel to increase total output up to 100+MW.

Renewable Integration

    • Designed to work with an array of renewable systems, including solar and wind
    • Seamless integration with Cat Microgrid Master Controller (MMC) allows for maximum renewable penetration and full asset control

Transient Assist

    When used with a generator set, the Cat PGS module will provide reserve power capacity to:
    • Decrease the transient voltage and frequency dips resulting from the application of large loads.
    • Enables highly-efficient lean-burn gas gensets to operate in island mode.

  March 27, 2024

Specifications

Units: 
Technical Summary
Application Transient Assist
Module Type Grid stabilization
Nameplate Power 767 kW | 1000 kW
Nameplate Energy Capacity 448 kWh | 672 kWh

Benefits & Features

Reliable and Scalable

    Factory prepackaged and tested
    • Pre-engineered containershipped as a single unit with batteries, inverter, isolation transformer and other equipment installed.
    • Parallel ready - multiple modules may be used in parallel to increase total output up to 100+MW.

Renewable Integration

    • Designed to work with an array of renewable systems, including solar and wind
    • Seamless integration with Cat Microgrid Master Controller (MMC) allows for maximum renewable penetration and full asset control

Transient Assist

    When used with a generator set, the Cat PGS module will provide reserve power capacity to:
    • Decrease the transient voltage and frequency dips resulting from the application of large loads.
    • Enables highly-efficient lean-burn gas gensets to operate in island mode.

Grid Stabilization

    • Protects against many typical power problems, including power failure, voltage sags/surges, and under/over frequency conditions.

High Performance Inverter

    • Built-in controls for the charging and discharging of the energy storage equipment.
    • Static VAR compensator.
    • Four-quadrant output power factor control.
    • Automatic anti-islanding to meet UL 1741 and synchronization back to grid.

Applicable Standards and Certifications

    UL Listed to the following standards (certification and mark pending):
    • UL 9540
    • UL 1741 SB
    • CSA C22.2 No. 107.1/16
    • cULus mark
    Declarations (pending):
    • CE Declaration of conformity
    • IEC60204-1

Standard Equipment

  • Power Grid Stabilization
    • Cat BDP bi-directional power inverter
    • Energy storage batteries
    • Color HMI touchscreen
    • Remote communications via Modbus TCP
    • HVAC system to maintain interior temperature
    • Liquid / Air cooling
    • Isolation Transformer
    • Convenience receptacles
    • Fire suppression system

View 360